Decking Sheets

TRAPEZOIDAL DECKING PANEL 945

DIMENSIONAL DRAWINGS



52-945" Profile (Fy = 250 MPA)

Thk.

Safe Span in Meter

 

0.1

0.125

0.15

0.175

0.2

0.225

0.25

0.6

0.80

8.50

7.74

9.86

25.73

7723

11.08

0.8

1.00

12.29

10.20

12.32

33.38

9278

15.17

1

1.20

12.43

11.56

14.73

38.32

11099

16.32

1.2

1.60

16.57

15.37

19.58

50.81

14766

21.41

1.6

2.00

20.71

19.14

24.39

63.02

19398

26.24

2

2.50

25.89

23.94

30.49

78.81

19936

32.46


"52-945" Profile (Fy = 345 MPA)

Thk.

Safe Span in Meter

 

0.1

0.125

0.15

0.175

0.2

0.225

0.25

0.6

2.45

2.25

2.1

2.025

1.925

1.85

1.775

0.8

2.9

2.675

2.5

2.35

2.25

2.15

2.05

1

3.2

2.975

2.775

2.625

2.475

2.375

2.275

1.2

3.5

3.25

3

2.875

2.725

2.59

2.475

1.6

4

3.7

3.45

3.25

3.1

2.95

2.83

2

4.45

4.1

3.8

3.6

3.425

3.275

3.125


O.1/0.125/0.15……/0.25 m : Slab Thickness measured from bottom of deck to TOC
0.6/0.8……./2 mm : Decking Thickness
Tabulated Figures : Safe Unsupported span i.e. Spacing of Beams

Design Parameters

»

The design is based on BS5950 Part 4
»
Construction load of 1.5 kN/Sq.m is used for all the cases
»
Total load is factored by 1.5 to arrive at design load
»
The width of support is taken as 150 mm to calculate the effective span of deck
»
The permissible deflection is taken as Span/180
»
The Slab thickness is the total thickness Up-to & including depth of deck panel

In addition to a wide range of profiles to choose from, our in- house design teams can also create custom profiles to suit every requirement. Floor Decking is one of the most effective methods of constructing floors in very useful in high-rise RCC/Steel Buildings and steel building. They are amalgamated into the floor concrete hence they serve the dual purpose of permanent form and positive reinforcement of the floor.
about_img about_img